The future of plating!

Plating Workshop

Everything you need to know about plating!

Posts in rectifiers
Understanding copper bussing for your chrome plating tank! Part 2 of 4

There are 2 main types of chrome plating tank bussing configurations. Most chrome shops us a three bar or two bar configuration. Also, there is a difference between rectifier bussing and tank bussing. Rectifier bussing - Transmits power from the rectifier to the tank. Tank bussing - transmits power to the bath and the part to be plating. Contact Plating International for more information! Info@PlatingInternational.com

Understanding copper bussing for your chrome plating tank! Part 1 of 4

In part 1 of this 4 part short video series, we will help you understand the complicated process of copper bussing your chrome tank properly. General rule : The diameter of the copper should be 1 sq in for each 1,000 amps carried. If the rectifier is more than 20 ft from the plating tank you may need thicker copper. Contact Plating International for more information! Info@PlatingInternational.com